INSTRUCTION MANUAL
(M060B01-03-14A)
Communications interface
CEM M-ETH
Zobrazit stránku 0
1 2 3 4 5 6 ... 23 24

Shrnutí obsahu

Strany 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL(M060B01-03-14A)Communications interfaceCEM M-ETH

Strany 2

3.4.- CONNECTION DIAGRAMThe connection between the CEM M-ETH and the Ethernet network must be made with a twisted pair cable (100B

Strany 3

4�- OPERATIONThe CEM M-ETH is designed to be used as a Ethernet port for any device in the CEM family, using the mechanical coupling next to the opti

Strany 4 - CONTENTS

Table 3:LINK LED, colour codesLINK LEDColour StatusFlashing red Unit not linkedSteady green Unit linked  LED LINK/ACT, indicates the state of the Eth

Strany 5 - REVISION LOG

Table 5 shows the format of the MODBUS/TCP frame.Table 5: MODBUS/TCP frame formatName Length FunctionTransaction identier 2 For message synchronisati

Strany 6

4�4�2�2�- EnergyThe Read function is implemented for these variables.Table 7: Modbus variables: EnergyDescription Address Size UnitsTotal values Imp

Strany 7

Descripción Dirección Tamaño UnidadesPhase 3 cos φ 0x0742 32 bits 2 decimal placesPhase 1 active power 0x0746 32 bits WPhase 2 active power 0x0748 32

Strany 8 - Figure 2

Opciones C10 C20 C30bytes en formato ASCIIAccuracyClass B active / Does not measure reactive energy  10Class B active / Class 2.0 reactive  12Me

Strany 9

4�4�2�7�- Available addresses by unitTable 13: Modbus variables: Available addresses by unit�Address C10 C20 C30 Description0x03E8  Modbus Address0

Strany 10 - Ethernet

Dirección C10 C20 C30 Descripción0x075C  Total apparent power0xF010  Energy meter model0x2710  Serial no.0x044CVoltage primary0x044EVoltage

Strany 11 - CEM M-ETH

5�- TECHNICAL FEATURESPower supplyRated voltage 230 V~ ± 20%Maximum power consumption 4 VAFrequency 50/60 Hz with no differentiationInsulationAC volt

Strany 12 - Table 4�

2CEM M-ETHInstruction Manual

Strany 13

35904535.55 446165Figure 7: CEM M-ETH dimensions 20CEM M-ETHInstruction Manual

Strany 14

6�- MAINTENANCE AND TECHNICAL SERVICE 7�- GUARANTEE• No returns will be accepted and no unit will be repaired or replaced if it is not ac-companied b

Strany 15

8�- CE CERTIFICATE22CEM M-ETHInstruction Manual

Strany 16

23Instruction ManualCEM M-ETH

Strany 17

CIRCUTOR, SA Vial Sant Jordi, s/n08232 -Viladecavalls (Barcelona)Tel.: (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 www.circutor.es central@circutor

Strany 18

SAFETY PRECAUTIONS DISCLAIMERCIRCUTOR, SA reserves the right to make modi cations to the device or the unit speci ca-tions set out in this instruct

Strany 19 - 5�- TECHNICAL FEATURES

CONTENTSSAFETY PRECAUTIONS ��������������������������������������������������������������������������������������������������������������������������

Strany 20 -

REVISION LOGTable 1: Revision log�Date Revision Description11/14 M060B01-03-14A Initial Version5Instruction ManualCEM M-ETH

Strany 21

1�- VERIFICATION UPON RECEPTIONCheck the following points upon receiving the unit: a) The unit meets the specications described in your order. b)

Strany 22 - 8�- CE CERTIFICATE

3�- UNIT INSTALLATION 3.1.- PRELIMINARY RECOMMENDATIONSIn order to use the unit safely, it is critical that the individuals who handle it fol-l

Strany 23

3.2.- INSTALLATIONOn the side of the unit are all of the indications adjusted to the CEI 62052-11 standard.The unit is installed on a DIN rail.

Strany 24 - Vial Sant Jordi, s/n

The unit must be connected to a power circuit that is protected with gL fuses (IEC 269) or M fus-es, with a rating of 0.5 to 2 A. It must be tted wit